2008Abstract
Risk of irreversible magnet demagnetization during short-circuit fault is analyzed in case of an axial-flux dual-rotor machine, using a three-dimensional finite-element method (3D-FEM). In order to validate the numerical model, calculated waveforms of the currents are compared with experimental results for short-circuit at low speeds. Then currents and magnetic flux density inside the magnets are computed for short-circuit at higher speeds in order to predetermine the maximum admissible speed for the machine.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Identification of a 7-phase claw-pole starter-alternator for a micro-hybrid automotive application Communication avec acteBRUYERE, Antoine; HENNERON, Thomas; SEMAIL, Eric; LOCMENT, Fabrice; BOUSCAYROL, Alain; DUBUS, Jean-Marc; MIPO, Jean-Claude (IEEE, 2008)This paper deals with the identification of a new high power starter-alternator system, using both: a Finite Element Method (FEM) modeling and an experimental vector control. The drive is composed of a synchronous 7-phase ...
-
Article dans une revue avec comité de lectureLOCMENT, Fabrice; PIRIOU, Francis; SEMAIL, Eric (Institute of Electrical and Electronics Engineers, 2006)In this paper, a 7-phase Axial-flux Double-rotor Permanent Magnet Synchronous Machine is studied using analytical and Finite Element methods. This type of machine shows a higher sensitivity to the inductance harmonics and ...
-
Communication avec acteBRUYERE, Antoine; BOUSCAYROL, Alain; CHARLEY, Jacques; LOCMENT, Fabrice; DUBUS, Jean-Marc; MIPO, Jean-Claude; SEMAIL, Eric (IEEE, 2008)This paper deals with the modeling and the control of a new high power 12V Integrated Starter Alternator (ISA). This system is used to bring micro-hybrid functions to standard Internal Combustion Engine (ICE) vehicles. The ...
-
Article dans une revue avec comité de lectureThis paper deals with fault tolerant multiphase electrical drives. The quality of the torque of a vector-controlled Permanent Magnet (PM) Synchronous Machine supplied by a multi-leg Voltage Source Inverter (VSI) is examined ...
-
Article dans une revue avec comité de lectureLOCMENT, Fabrice; SEMAIL, Eric; KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2008)This paper deals with easy-to-implement control strategies when a seven-phase axial flux permanent magnet machine supplied by a seven-leg voltage source inverter is in fault operation mode. Using a vectorial multimachine ...