Five-Phase Bi-Harmonic PMSM Control under Voltage and Currents Limits
Communication avec acte
Résumé
For a particular five-phase synchronous machine, this paper investigates the sensitivity of a vectorial control strategy on the required peak phase voltage whose value is fundamental for the choice of the DC bus voltage. The specificity of the machine is that the first and third harmonic components of the back electromotive force (back-emf) have the same amplitude. As a consequence, the torque can be produced by one of them or both with suitable currents. This degree of freedom is interesting for optimizing the efficiency and generating high transient torque. However, using two harmonics having the same amplitude leads to a necessity to analyze the constraints on the required phase machine voltage. Considering a Maximum Torque Per Ampere (MTPA) strategy, the paper examines the impact of some parameters such as the phase shift between currents and back-emfs or the ratio between the third and the first harmonic of current on the torque and maximum voltage value. Experimental tests with a limited DC bus voltage have been carried out and compared to the results obtained by a Finite Element Analysis.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication sans acte/
-
Communication avec acteTRABELSI, Mohamed; SEMAIL, Eric; MEINGUET, Fabien; NGUYEN, Ngac Ky (IEEE - Power and Energy Society, 2016)This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For such applications, the fault ...
-
Article dans une revue avec comité de lectureTRABELSI, Mohamed; SEMAIL, Eric; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2017)This paper proposes a procedure that is suitable for experimental investigation of real-time open-switch and open-phase faults diagnosis of a five-leg Voltage Source Inverter (VSI) feeding a five-phase bi-harmonic Permanent ...
-
Communication avec acteThis paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric ...
-
Article dans une revue avec comité de lectureTRABELSI, Mohamed; SEMAIL, Eric; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)A novel centroid-based diagnostic method of the power switches in five-leg Voltage Source Inverter (VSI) is proposed in this paper. Using a vectorial multi-machine description, a five-phase drive presenting an opened switch ...