Modelling of corrosion fatigue crack initiation on martensitic stainless steel in high cycle fatigue regime
Article dans une revue avec comité de lecture
Date
2018Journal
Corrosion ScienceRésumé
This paper presents an analytical model for assessing the corrosion fatigue crack initiation life on a martensitic stainless steel X12CrNiMoV12-3 in high cycle fatigue regime (between 105 and 107 cycles). Based on in-situ electrochemical measurements during corrosion fatigue tests in NaCl aqueous solution, the corrosion fatigue crack initiation mechanism was identified. Two main stages were investigated: (i) the fracture of the passive film by slip bands and (ii) the free dissolution of the metal developing fatigue crack initiation from a critical corrosion defect. The depassivation stress threshold corresponds to the median fatigue strength at 107 cycles for fatigue corrosion tests. For an applied stress range less than this threshold, the depassivation phenomenon was not observed at 107 cycles and no crack initiation occurred. The proposed model takes into account the depassivation process induced by the slip bands emergence at the specimen surface and the corrosion rate under cyclic loading. The experimental results are compared to the proposed model taking into account mechanical and electrochemical material parameters.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureThis paper proposes a volumetric high cycle fatigue (HCF) strength criterion able to quantify the influence of natural corrosion pits on the fatigue limit of a martensitic stainless steel with high mechanical strength. ...
-
Effect of Corrosion on the High Cycle Fatigue Strength of Martensitic Stainless Steel X12CrNiMoV12-3 Article dans une revue avec comité de lectureThis paper addresses the effects of corrosion on the high cycle fatigue (HCF) strength of a high mechanical strength martensitic stainless steel (X12CrNiMoV12-3) that is used in aeronautic applications. HCF tests (between ...
-
Article dans une revue avec comité de lectureMESSAGER, Alexandre; JUNET, Arnaud; PALIN-LUC, Thierry; BUFFIERE, Jean-Yves; EL MAY, Mohamed; GAILLARD, Yves; KING, Andrew; BONNIN, Anne; NADOT, Yves; RANC, Nicolas; SAINTIER, Nicolas (Wiley-Blackwell, 2020)This work presents a new ultrasonic fatigue testing device for studying the initiation and propagation mechanisms of internal microstructurally short fatigue cracks using in situ synchrotron tomography. Its principle is ...
-
Article dans une revue avec comité de lectureBIDOUARD, Hadrien; PALIN-LUC, Thierry; SAINTIER, Nicolas; DUMAS, Christian; EL DSOKI, Chalid; KAUFMANN, Heinz; SONSINO, Cetin Morris (2009)Fatigue tests were performed on ferritic bainitic steel notched specimens (Kt = 2.5) under load controlled constant amplitude loading. These tests show that under constant amplitude tension compression loading, periodical ...
-
Article dans une revue avec comité de lectureSAINTIER, Nicolas; PALIN-LUC, Thierry; EL DSOKI, Chalid; BIDONARD, Hadrien; KAUFMANN, Heinz; DUMAS, Christian; VÖLLMECKE, F.J.; SONSINO, Cetin Morris (Wiley-VCH Verlag, 2011)Load controlled fatigue tests were performed up to 107 cycles on flat notched specimens (Kt =2.5) under constant amplitude and variable amplitude loadings with and without periodical overloads. Two materials are studied: ...