Open-Phase Fault Operation of 5-Phase Induction Motor Drives using DTC Techniques
Communication avec acte
Author
Abstract
Direct torque control (DTC) is extensively used in conventional three-phase drives as an alternative to field-oriented control methods. The standard DTC technique was originally designed to regulate two independent variables using hysteresis controllers. Recent works have extended the procedure for five-phase drives in healthy operation accounting for the additional degrees of freedom. Although one of the main advantages of multiphase machines is the ability to continue the operation in faulty conditions, the utility of DTC after the appearance of a fault has not been covered in the literature yet. This paper analyses the operation of a five-phase induction motor drive in faulty situation using a DTC controller. An open-phase fault condition is considered, and simulation results are provided to study the performance of the drive, comparing with the behavior during healthy state.
Files in this item
- Name:
- L2EP_IECON_2015_BERMUDEZ.pdf
- Size:
- 991.7Kb
- Format:
- Description:
- Article Principal
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureBERMUDEZ GUZMAN, Mario; GONZALEZ PRIETO, Ignacio; BARRERO, Federico; GUZMAN, Hugo; DURAN, Mario Javier; KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2018)Direct torque control (DTC) has been recently used for the development of high-performance five-phase induction motor (IM) drives, where normal operation of the system has been usually considered and the ability of DTC to ...
-
Article dans une revue avec comité de lectureBERMUDEZ GUZMAN, Mario; GONZALEZ PRIETO, Ignacio; BARRERO, Federico; GUZMAN, Hugo; DURAN, Mario Javier; KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2017)Direct torque control (DTC) has been widely used as an alternative to traditional field-oriented control (FOC) methods for three-phase drives. The conventional DTC scheme has been successfully extended to multiphase drives ...
-
Communication avec acteBERMUDEZ GUZMAN, Mario; GUZMAN, Hugo; GONZALEZ PRIETO, Ignacio; BARRERO, Federico; DURAN, Mario Javier; KESTELYN, Xavier (IECON 2015 - 41st Annual Conference of the IEEE Industrial Electronics Society, 2015)Direct Torque Control (DTC) technique has been applied in recent times in high performance five-phase induction motor drives during the normal operation of the system. The use of DTC in the multiphase area is far from ...
-
Article dans une revue avec comité de lectureMARTIN, Cristina; BERMUDEZ GUZMAN, Mario; BARRERO, Federico; ARAHAL, Manuel R.; DURAN, Mario Javier; KESTELYN, Xavier (Elsevier, 2017)Model predictive control techniques have been recently proposed as a viable control alternative for power converters and electrical drives. The good current tracking, flexible control design or reduced switching losses are ...
-
Communication avec acteBERMUDEZ GUZMAN, Mario; GOMOZOV, Oleg; SEMAIL, Eric; BARRERO, Federico; KESTELYN, Xavier; NGUYEN, Ngac Ky (ELECTRIMACS, 2017)Multiphase machines have recently gained importance in the research community for their use in applications where high power density, wide speed range and fault-tolerant capabilities are needed. The optimal control of such ...