Open Switch Fault Effects Analysis in Five-Phase PMSM Designed for Aerospace Application

Communication avec acte
Auteur
TRABELSI, Mohamed
ccSEMAIL, Eric
MEINGUET, Fabien
48530 Thales Alenia Space [Toulouse] [TAS]
NGUYEN, Ngac Ky
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]

URI
http://hdl.handle.net/10985/14580
Date
2016

Résumé

This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For such applications, the fault tolerance and the reliability of the drive (PMSM and the power converter) are important to take into account for design. The addressed work aims essentially to analyze the dynamic of the measured phase currents in post-fault operation with a real-time fault diagnostic purpose in the VSI. The paper starts with a presentation of the electric drive system structure and its control used in pre-fault and post-fault operation. Then, fault effects analysis (FEA) on the system will be considered. All results are verified analytically and through simulation software using Matlab/Simulink®. The theoretical development and the simulation results show that the five-phase PMSM under inverter faults presents typical characteristics which can be used as better input variables for designing a high performance real-time fault diagnostic and classification process.

Fichier(s) constituant cette publication

Nom:
L2EP_SPEEDAM_2016_NGUYEN
Taille:
1.029Mo
Format:
PDF
Description:
Article Principal
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • Open Switch Fault Effects Analysis (OSFEA) in Five Phase PMSM Designed for Aerospace Application 
    Communication avec acte
    TRABELSI, Mohamed; ccSEMAIL, Eric; MEINGUET, Fabien; NGUYEN, Ngac Ky (IEEE, 2016)
    This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For these demanding applications, ...
  • Inverter Open Circuit Faults Diagnosis in Series-Connected Six-Phases Permanent Magnet Drive 
    Communication avec acte
    DOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; TRABELSI, Mohamed; ccSEMAIL, Eric; NGUYEN, Ngac Ky (SDEMPED, 2017)
    This paper deals with the fault effects analysis and diagnosis in 6-Φ PMSM designed for aerospace applications. The addressed work aims to analyze the features offered by the space vector theory applied to these systems ...
  • Open-Switch and Open-Phase Real Time FDI Process for Multiphase PM Synchronous Motors 
    Communication avec acte
    TRABELSI, Mohamed; MEINGUET, Fabien; ccSEMAIL, Eric; NGUYEN, Ngac Ky (ISIE Conference, 2016)
    This paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric ...
  • Inverter Fault Diagnosis of an Electrical Series-Connected Two Sinusoidal Six-Phase Permanent Magnet Machines Drive 
    Article dans une revue avec comité de lecture
    JOSE DOS SANTOS MORAES, Tiago; TRABELSI, Mohamed; NGUYEN, Ngac Ky; ccSEMAIL, Eric; MEINGUET, Fabien (Institution of Engineering and Technology, 2020)
    This paper investigates a real-time fault diagnostic of a transportation system which needs two drives with fault-tolerance capabilities. Because of constraints on the mass of the system and on the cost of the Voltage ...
  • Commande en Mode Dégradé d’un Drive avec Deux Machines 6 phases en Série 
    Communication avec acte
    DOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; ccSEMAIL, Eric; NGUYEN, Ngac Ky (SGE 2016, 2016)
    Dans le cadre d’une commande en mode dégradé d’un entrainement comprenant deux machines polyphasées connectées en série et pilotées de façon indépendante, l’article s’intéresse à analyser la performance de l’entrainement ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts

Lettre Diffuser la Science

Dernière lettreVoir plus

Statistiques de consultation

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales