Measuring extension of the lumbar-pelvic-femoral complex with the EOS® system.

Article dans une revue avec comité de lecture
Author
LAZENNEC, Jean-Yves
484605 LBM/institute de Biomécanique humaine Georges Charpak
BRUSSON, Adrien
353778 CHU Pitié-Salpêtrière [AP-HP]
FOLINAIS, Dominique
533181 Clinique Maussins-Nollet
ZHANG, A
POUR, Aidin Eslam
24332 University of Michigan [Ann Arbor]
ROUSSEAU, Marc-Antoine
484605 LBM/institute de Biomécanique humaine Georges Charpak

URI
http://hdl.handle.net/10985/18116
DOI
10.1007/s00590-015-1603-8
Date
2015
Journal
European Journal of Orthopaedic Surgery & Traumatology

Abstract

Introduction Sagittal balance of the coxofemoral joint in standing position and its extension capacity determine hip/spine adaptation, especially in relation to pelvic retroversion, which may be age-associated or follow either spinal arthrodesis or vertebral osteotomies. The concept of extension reserve is essential for assessing posterior hip impingement. The global visualization of the lumbar–pelvic–femoral complex obtained by EOS® imaging enables this sagittal analysis of both the subpelvic region and lumbar spine by combining the reference standing position and the possibility of dynamic tests. Materials and methods We studied 46 patients and their 92 hips. The EOS® radiography was performed in neutral standing position and with one foot on a step, alternately the right and left feet. Pelvic incidence, sacral slope, pelvic version, and femoral version were measured twice by two operators. The global extension reserve (GER) was defined by the sum of the intrinsic extension reserve (allowed by the hips, IER) and the extrinsic extension reserve (allowed by the spine, EER). The IER for each hip corresponds to the difference in the sacrofemoral angle (SFA) for each of the two positions. The EER was measured by the difference in the sacral slope. A descriptive study was performed, together with studies of inter- and intra-observer reproducibility, right/left symmetry, and an analysis according to age, sex, and BMI. Results The mean femoral version in the reference position was 11.7° (SD 14.3°). The reproducibility of the SFA measurement was statistically verified. The IER (mean 8.8°), EER (mean −0.7°), and GER (mean 8.2°) all differed significantly between the two sides for each patient and were not associated with age, sex, or BMI. Discussion The femoral axis is not perpendicular to the ground in neutral position, contrary to the conventional view of this position. The measurements proposed for dynamic sagittal analysis of the hip are reproducible and make it possible to identify the IER within the GER of the spinal–pelvic–femoral complex. Conclusion The assessment of the lumbar–pelvic–femoral complex by EOS imaging makes it possible to define the intrinsic and extrinsec extension reserves to describe the reciprocal adaptive capacities of the hips and spine. Level of evidence IV.

Files in this item

Name:
IBHGC_EJOST_2015_LAZENNEC.pdf
Size:
782.6Kb
Format:
PDF
Description:
Article
View/Open

Collections

  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)

Related items

Showing items related by title, author, creator and subject.

  • Total Hip Prostheses in Standing, Sitting and Squatting Positions: An Overview of Our 8 Years Practice Using the EOS Imaging Technology 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; ROUSSEAU, Marc-Antoine; BRUSSON, Adrien; FOLINAIS, Dominique; AMEL, Maria; CLARKE, Ian; POUR, Aidin Eslam (2015)
    More total hip arthroplasty (THA) is performed worldwide and especially in younger and more active patients compared to earlier decades. One of the focuses of THA research in the future will be on optimizing the radiological ...
  • Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; BRUSSON, Adrien; FOLINAIS, Dominique; ROUSSEAU, Marc-Antoine; POUR, Aidin Eslam (Springer Verlag, 2015)
    Purpose Accurate evaluation of femoral offset is difficult with conventional anteroposterior (AP) X-rays. The EOS imaging system is a system that makes the acquisition of simultaneous and orthogonal AP and lateral images ...
  • Do Patients’ Perceptions of Leg Length Correlate With Standing 2- and 3-Dimensional Radiographic Imaging? 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; BRUSSON, Adrien; ROUSSEAU, Marc-Antoine; ROBBINS, Christopher B.; POUR, Aidin Eslam (Elsevier, 2016)
    BACKGROUND: This study compared 2- and 3-dimensional (2D and 3D) radiographic measurements of anatomical and functional leg length and knee coronal and sagittal alignments and correlated these measurements with patients' ...
  • The global alignment in patients with lumbar spinal stenosis: our experience using the EOS full-body images 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; FOLINAIS, Dominique; BENDAYA, Samy; ROUSSEAU, Marc-Antoine; POUR, Aidin Eslam (Springer-Verlag, 2016)
    Lumbar stenosis is frequently observed and treated by spine surgeons. The extent of neurological decompression and the potential spinal fixation are the basic concerns when surgery is planned. But this segmented approach ...
  • Clinical outcomes, radiologic kinematics, and effects on sagittal balance of the 6 df LP-ESP lumbar disc prosthesis 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; EVEN, Julien; ccSKALLI, Wafa; RAKOVER, Jean-Patrick; BRUSSON, Adrien; ROUSSEAU, Marc-Antoine (Elsevier BV, 2014)
    Background context: Surgical treatment of degenerative disc disease remains a controversial subject. Lumbar fusion has been associated with a potential risk of segmental junctional disease and sagittal balance misalignment. ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales