Total Hip Prostheses in Standing, Sitting and Squatting Positions: An Overview of Our 8 Years Practice Using the EOS Imaging Technology

Article dans une revue avec comité de lecture
Author
LAZENNEC, Jean-Yves
1001017 Institut de Biomécanique Humaine Georges Charpak [IBHGC]
ROUSSEAU, Marc-Antoine
1001017 Institut de Biomécanique Humaine Georges Charpak [IBHGC]
BRUSSON, Adrien
353778 CHU Pitié-Salpêtrière [AP-HP]
FOLINAIS, Dominique
AMEL, Maria
542005 Cellule Pasteur UPMC
CLARKE, Ian
506003 Loma Linda University
POUR, Aidin Eslam
24332 University of Michigan [Ann Arbor]

URI
http://hdl.handle.net/10985/18639
DOI
10.2174/1874325001509010026
Date
2015
Journal
The Open Orthopaedics Journal

Abstract

More total hip arthroplasty (THA) is performed worldwide and especially in younger and more active patients compared to earlier decades. One of the focuses of THA research in the future will be on optimizing the radiological follow-up of these patients using 2D and 3D measurements of implants position while reducing the radiation dose delivered. Low-dose EOS(®) imaging is an innovative slot-scanning radiograph system providing valuable information in patient functional positions (standing, sitting and even squatting positions). EOS has been proven accurate and reliable without significant inconvenience caused by the metallic artifacts of implants. The ability to obtain precise data on implant orientation according to the patient posture opens new perspectives for a comprehensive analysis of the pelvic frontal and sagittal balance and its potential impact on implants function and failures. We report our 8 years experience on our first 300 THA patients using this technology routinely for pre and post op evaluation. Our results will be compared and confronted with the actual literature about this innovative technology. We shall especially emphasize our experience about patients with abnormal posture and the evolution of the subject over time, because the phenomenon of an aging spine is frequently associated with the process of aging hips.

Files in this item

Name:
IBHGC_OOJ_2015_LAZENNEC.pdf
Size:
3.073Mb
Format:
PDF
Description:
Article
View/Open

Collections

  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)

Related items

Showing items related by title, author, creator and subject.

  • Offset and anteversion reconstruction after cemented and uncemented total hip arthroplasty: an evaluation with the low-dose EOS system comparing two- and three-dimensional imaging 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; BRUSSON, Adrien; FOLINAIS, Dominique; ROUSSEAU, Marc-Antoine; POUR, Aidin Eslam (Springer Verlag, 2015)
    Purpose Accurate evaluation of femoral offset is difficult with conventional anteroposterior (AP) X-rays. The EOS imaging system is a system that makes the acquisition of simultaneous and orthogonal AP and lateral images ...
  • Measuring extension of the lumbar-pelvic-femoral complex with the EOS® system. 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; BRUSSON, Adrien; FOLINAIS, Dominique; ZHANG, A; POUR, Aidin Eslam; ROUSSEAU, Marc-Antoine (Springer-Verlag, 2015)
    Introduction Sagittal balance of the coxofemoral joint in standing position and its extension capacity determine hip/spine adaptation, especially in relation to pelvic retroversion, which may be age-associated or follow ...
  • Do Patients’ Perceptions of Leg Length Correlate With Standing 2- and 3-Dimensional Radiographic Imaging? 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; BRUSSON, Adrien; ROUSSEAU, Marc-Antoine; ROBBINS, Christopher B.; POUR, Aidin Eslam (Elsevier, 2016)
    BACKGROUND: This study compared 2- and 3-dimensional (2D and 3D) radiographic measurements of anatomical and functional leg length and knee coronal and sagittal alignments and correlated these measurements with patients' ...
  • The global alignment in patients with lumbar spinal stenosis: our experience using the EOS full-body images 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; FOLINAIS, Dominique; BENDAYA, Samy; ROUSSEAU, Marc-Antoine; POUR, Aidin Eslam (Springer-Verlag, 2016)
    Lumbar stenosis is frequently observed and treated by spine surgeons. The extent of neurological decompression and the potential spinal fixation are the basic concerns when surgery is planned. But this segmented approach ...
  • Clinical outcomes, radiologic kinematics, and effects on sagittal balance of the 6 df LP-ESP lumbar disc prosthesis 
    Article dans une revue avec comité de lecture
    LAZENNEC, Jean-Yves; EVEN, Julien; ccSKALLI, Wafa; RAKOVER, Jean-Patrick; BRUSSON, Adrien; ROUSSEAU, Marc-Antoine (Elsevier BV, 2014)
    Background context: Surgical treatment of degenerative disc disease remains a controversial subject. Lumbar fusion has been associated with a potential risk of segmental junctional disease and sagittal balance misalignment. ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales