• français
    • English
    English
  • Ouvrir une session
Aide
Voir le document 
  •   Accueil de SAM
  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)
  • Voir le document
  • Accueil de SAM
  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)
  • Voir le document
JavaScript is disabled for your browser. Some features of this site may not work without it.

Accuracy evaluation of CAD/CAM generated splints in orthognathic surgery: a cadaveric study

Article dans une revue avec comité de lecture
Auteur
SCHOUMAN, Thomas
IMHOLZ, Benoït
FASEL, Jean
COURVOISIER, Delphine
SCOLOZZI, Paolo
ccROUCH, Philippe
1001017 Institut de Biomécanique Humaine Georges Charpak [IBHGC]

URI
http://hdl.handle.net/10985/18398
DOI
10.1186/s13005-015-0082-9
Date
2015
Journal
Head and Face Medicine

Résumé

Introduction To evaluate the accuracy of CAD/CAM generated splints in orthognathic surgery by comparing planned versus actual post-operative 3D images. Methods Specific planning software (SimPlant® OMS Standalone 14.0) was used to perform a 3D virtual Le Fort I osteotomy in 10 fresh human cadaver heads. Stereolithographic splints were then generated and used during the surgical procedure to reposition the maxilla according to the planned position. Pre-operative planned and postoperative 3D CT scan images were fused and imported to dedicated software (MATLAB®) 7.11.) for calculating the translational and rotational (pitch, roll and yaw) differences between the two 3D images. Geometrical accuracy was estimated using the Root Mean Square Deviations (RMSD) and lower and upper limits of accuracy were computed using the Bland & Altman method, with 95 % confidence intervals around the limits. The accuracy cutoff was set at +/− 2 mm for translational and ≤ 4° for rotational measurements. Results Overall accuracy between the two 3D images was within the accuracy cutoff for all values except for the antero-posterior positioning of the maxilla (2.17 mm). The translational and rotational differences due to the splint were all within the accuracy cutoff. However, the width of the limits of agreement (range between lower and upper limits) showed that rotational differences could be particularly large. Conclusion This study demonstrated that maxillary repositioning can be accurately approximated and thus predicted by specific computational planning and CAD/CAM generated splints in orthognathic surgery. Further study should focus on the risk factors for inaccurate prediction.

Fichier(s) constituant cette publication

Nom:
IBHGC_HFM_2015_ROUCH.pdf
Taille:
2.706Mo
Format:
PDF
Description:
Article
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Institut de Biomécanique Humaine Georges Charpak (IBHGC)

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • Experiences with a new biplanar low-dose X-ray device for imaging the facial skeleton: A feasibility study 
    Article dans une revue avec comité de lecture
    BERG, Britt-Isabelle; LAVILLE, Aurélien; COURVOISIER, Delphine S.; SCHOUMAN, Thomas; ccROUCH, Philippe (Public Library of Science, 2020)
    Methods We evaluated 48 biplanar radiographs from 12 patients (posteroanterior/lateral), originally taken for a scoliosis examination with a biplanar low-dose X-ray device. For this study, the images were further evaluated ...
  • Zygomatic bone shape in intentional cranial deformations: a model for the study of the interactions between skull growth and facial morphology 
    Article dans une revue avec comité de lecture
    KETOFF, Serge; GIRINON, François; SCHLAGER, Stefan; FRIESS, Martin; SCHOUMAN, Thomas; KHONSARI, Roman Hossein; ccROUCH, Philippe (Wiley, 2016)
    Intentional cranial deformations (ICD) were obtained by exerting external mechanical constraints on the skull vault during the first years of life to permanently modify head shape. The repercussions of ICD on the face are ...
  • Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep. 
    Article dans une revue avec comité de lecture
    SCHOUMAN, Thomas; SCHMITT, Mary; ADAM, Clayton; DUBOIS, Guillaume; ccROUCH, Philippe (Elsevier, 2016)
    The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were ...
  • Accuracy and reliability of automatic three-dimensional cephalometric landmarking 
    Article dans une revue avec comité de lecture
    DOT, Gauthier; RAFFLENBEUL, Frédéric; ARBOTTO, M.; SCHOUMAN, Thomas; ccROUCH, Philippe; ccGAJNY, Laurent (Elsevier, 2020)
    The aim of this systematic review was to assess the accuracy and reliability of automatic landmarking for cephalometric analysis of three-dimensional craniofacial images. We searched for studies that reported results of ...
  • Fully automatic segmentation of craniomaxillofacial CT scans for computer-assisted orthognathic surgery planning using the nnU-Net framework 
    Article dans une revue avec comité de lecture
    DOT, Gauthier; SCHOUMAN, Thomas; DUBOIS, Guillaume; ccROUCH, Philippe; ccGAJNY, Laurent (Springer Science and Business Media LLC, 2022)
    Objectives To evaluate the performance of the nnU-Net open-source deep learning framework for automatic multi-task segmentation of craniomaxillofacial (CMF) structures in CT scans obtained for computer-assisted orthognathic ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts

Lettre Diffuser la Science

Dernière lettreVoir plus

Statistiques de consultation

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales