A Mechanical Descriptor of Instability in Human Locomotion: Experimental Findings in Control Subjects and People with Transfemoral Amputation
Article dans une revue avec comité de lecture
Abstract
While multiple criteria to quantify gait instability exist, some limitations hinder their computation during realistic walking conditions. A descriptor, computed as the distance between the center of mass of the body and the minimal moment axis ( dCOM−Δ) , has been proposed recently. This present study aims at characterizing the behavior of the mentioned descriptor in a population at a higher risk of falls. Five individuals with transfemoral amputation and 14 healthy individuals were involved in an experiment composed of motion capture and force plates acquisition during overground walking at a self-selected speed. For both groups of participants, the profile of dCOM−Δ was analyzed and descriptive parameters were calculated. The plot of dCOM−Δ was different between groups and different relative to the leading limb considered (prosthetic or contralateral). All descriptive parameters calculated, except one, were statistically different between groups. As a conclusion, amputees seem to be able to limit the average of dCOM−Δ in spite of a different evolution pattern. This is consistent with the ability of the subjects to maintain their dynamic balance. However, the extracted parameters showed the significant asymmetry of the gait profile between prosthetic and contralateral stances and highlighted the potential sources of imbalance.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureAccurate calibration of the medio-lateral axis of the femur is crucial for clinical decision making based on gait analysis. This study proposes a protocol utilizing biplanar radiographs to provide a reference medio-lateral ...
-
Article dans une revue avec comité de lectureBASCOU, Joseph; SAURET, Christophe; VASLIN, Philippe; THOREUX, Patricia; LAVASTE, François; PILLET, Helene (Taylor & Francis, 2012)This article presents an examination and validation of a method to measure the field deceleration of a manual wheelchair (MWC) and to calculate the rolling resistances properties of the front and rear wheels. This method ...
-
Article dans une revue avec comité de lectureAccurate localisation of the hip joint centre is required to obtain accurate kinematics, kinetics and musculoskeletal modelling results. Literature data showed that conclusions drawn from synthetic data, adult normal ...
-
Chapitre d'ouvrage scientifiqueBERRIOT, Audrey; FOUGERON, Nolwenn; BONNET, Xavier; ROHAN, Pierre-Yves; PILLET, Helene (Springer International Publishing, 2021)The proper management of the local mechanical environment within soft tissues is a key challenge central the prevention of Pressure Ulcers (PUs). Magnetic Resonance (MR) imaging is the preferred imaging modality to measure ...
-
Comparison of scapula soft tissue artefact compensation methods during manual wheelchair locomotion Article dans une revue avec comité de lectureROUVIER, Théo; LIVET, C.; LOMBART, Antoine; DUMONT, Georges; PONTONNIER, C.; SAURET, Christophe; PILLET, Helene (Elsevier BV, 2022-09)Two third of manual wheelchair (MWC) users report suffering or having suffered from shoulder pain or injury [1]. To favour the understanding of these disorders, it is crucial to quantify the shoulder kinematics and kinetics ...