Virtual current vector‐based method for inverter open‐switch and open‐phase fault diagnosis in multiphase permanent magnet synchronous motor drives
Article dans une revue avec comité de lecture
Résumé
Multiphase permanent magnet synchronous motor (PMSM) drives. First defined are adequate variables called virtual current vectors. The projection of the zero‐sequence current component on these variables was used to define two simple fault indices. High sensitivity to fault is thus induced but with a good robustness to transient states and variation of machine parameters. The mathematical development of the proposed method is provided and supported by experimental tests conducted on two prototypes of multiphase machines in the laboratory: sinusoidal and bi‐harmonic PMSMs. The experimental results confirm the effectiveness and the robustness of the proposed method and its capability to detect the single and multiple open‐switches and open‐phase faults in the electric drive.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteTRABELSI, Mohamed; SEMAIL, Eric; MEINGUET, Fabien; NGUYEN, Ngac Ky (IEEE - Power and Energy Society, 2016)This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For such applications, the fault ...
-
Communication avec acteThis paper deals with the real time Fault Detection and Identification (FDI) process of inverter Open Switch Fault (OSF) and Open Phase Fault (OPF) in five-phase PMSM designed for aerospace applications in which the electric ...
-
Article dans une revue avec comité de lectureGONG, Jinlin; ZAHR, Hussein; TRABELSI, Mohamed; ASLAN, Bassel; SEMAIL, Eric; SCUILLER, Franck (Institute of Electrical and Electronics Engineers, 2018)In the context of traction drives with required torque transient capabilities and a classically wide flux weakening speed range, this paper gives design considerations of a particular Double-Polarity (DP) five-phase machine. ...
-
Communication avec acteThis paper presents a comparative evaluation of fault tolerant control strategies for a five-phase Permanent Magnet Synchronous Machine (PMSM) under an opened-phase fault mode. Two main classical Fault Tolerant Control ...
-
Communication avec acteThis paper analyses the copper losses due to the homopolar current of a five-phase open-end winding machine supplied by a 10-leg inverter and a single DC voltage source. This topology can have non-null high frequency ...