Flux-Weakening Strategies for a Five-Phase PM Synchronous Machine
Communication avec acte
Date
2011Résumé
In order to get a low cost mild hybrid system, a global objective is to keep the actual thermal engine architecture. As consequence, the current clawpole synchronous automotive generator must be replaced by a new more powerful electrical machine but with the same large speed range [0 -18000 rpm]. In the project, a power of 15 kW and a DC bus voltage of 60V have been chosen to provide a regenerative breaking at minimum cost. With this payload (250A for the DC bus current), a five-phase machine appears to be interesting because MOSFET transistors of the voltage source inverter (VSI) have not to be used in parallel configuration (only two rated 150A transistors per leg for the VSI). As the speed range is large, a flux weakening must be applied. As the five-phase drives have more degrees of freedom than three-phase ones, different flux weakening strategies can be considered. The aim of this paper is to compare one of them.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteLU, Li; ASLAN, Bassel; KOBYLANSKI, Luc; SANDULESCU, Paul; MEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2012)Multi-phase synchronous machines are more and more used in specific applications where high power density, low bus voltage, wide speed range and fault-tolerant capabilities are required. Due to the high number of degrees ...
-
Communication avec acteMEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ...
-
Communication avec acteBARRE, Pierre-Jean; BOUSCAYROL, Alain; DELARUE, Philippe; DUMETZ, Eric; GIRAUD, Frédéric; HAUTIER, Jean-Paul; LEMAIRE-SEMAIL, Betty; SEMAIL, Eric; KESTELYN, Xavier (IEEE, 2006)Causal Ordering Graph and Energetic Macroscopic Representation are graphical descriptions to model electromechanical systems using integral causality. Inversion rules have been defined in order to deduce control structure ...
-
Article dans une revue avec comité de lectureAfter a short historic of the multiphase machines and the state of the art of their open-circuited phase operation, this paper deals with a decoupled three-phase motor drive using a synchronous or induction machine. The ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...