Experimental study of the instationary flow between two ducted Counter-rotating rotors
Article dans une revue avec comité de lecture
Date
2013Journal
Journal of Engineering for Gas Turbines and PowerRésumé
The purpose of this work is to study experimentally the aerodynamic characteristics of a subsonic counter-rotating axial-flow fans system operating in a ducted configuration. The fans of diameter D = 375 mm were designed to match the specification point using an original iterative method: the front rotor blade cascade is designed with a conventional inverse method, setting the radial distribution of the Euler work. The through-flow is then computed using an axisymmetric and radial equilibrium asumption, with empirical models of losses. The rear rotor is not conventional but is designed to straighten the radial profile of the tangential velocity. The design of the front rotor is then modified until the stage meets the requirements. The experimental setup is arranged such that the rotation rate of each fan is independently controlled and that the axial distance between the rotors can be varied from 17% to 310% of the mid-span chord length. Systematic measurements of the global performances and local measurements of the velocity field and of the wall pressure fluctuations are performed, in order to first validate the design method, and to explore the effects of the two specific free parameters of the system: the axial spacing and the ratio of rotation rates. The results show that the efficiency is strongly increased compared to a conventional rotor or to a rotor-stator stage. The developed design method slightly over-predicts the pressure rise and slightly under-predicts the best ratio of rotation rates. Flow angle measurements downstream of the stage show that the outflow is not completely straightened at the design point. Finally, the system is highly efficient on a wide range of flow-rates and pressure rises: this system has thus a very flexible use, with a large patch of high efficient operating points in the parameter space.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureThe purpose of this work is to study the effects of blade thickness on the performances of an axial-flow fan. Two fans that differ only in the thickness of their blades were studied. The first fan was designed to be part of ...
-
Article dans une revue avec comité de lectureNOURI, Hussain; SARRAF, Christophe; REY, Robert; RAVELET, Florent; BAKIR, Farid (American Society of Mechanical Engineers, 2012)An experimental study on the design of counter-rotating axial-flow fans was carried out. The fans were designed using an inverse method. In particular, the system is designed to have a pure axial discharge flow. The ...
-
Communication avec acteAn experimental study on counter-rotating axial-flow fans was carried out. The fans of diameter D = 375 mm were designed using an inverse method. The counter-rotating fans operate in a ducted-flow configuration and the ...
-
Article dans une revue avec comité de lectureThe purpose of this work is to study the effects of blade thickness on the performances of an axial-flow fan. Two fans that differ only in the thickness of their blades were studied. The first fan was designed to be part ...
-
Communication avec acteAn experimental investigation on the aerodynamic performances of thick blades axial-flow fans was carried out in this study. Two fans are considered, the first one is rotomoulded (in plastic) and the second one is milled ...