Effects of LCF Loadings on the HCF Life of Notched Specimens in Ferritic-Bainitic Steel
Article dans une revue avec comité de lecture
Abstract
Fatigue tests were performed on ferritic bainitic steel notched specimens (Kt = 2.5) under load controlled constant amplitude loading. These tests show that under constant amplitude tension compression loading, periodical overloads application have a detrimental effect on the fatigue crack initiation strength for fully reversed load (R σ = — 1), while they have no influence under pulsating loading (R σ = 0). A finite element analysis shows that in the fully reversed tension (R σ = — 1), the stabilized cyclic behaviour at the notch root is an elastic-plastic shakedown while elastic shakedown is obtained under pulsated regime (R σ = 0), so that we can consider that the local cyclic behaviour has an influence on the overload effect. However, the overload application does not imply a remarkable modification of the stress and strain field under the subsequent constant amplitude loading and can not explain such a fatigue strength decrease in fully reversed tension.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureBIDOUARD, Hadrien;
PALIN-LUC, Thierry; SAINTIER, Nicolas; DUMAS, Christian; EL DSOKI, Chalid; KAUFMANN, Heinz; SONSINO, Cetin Morris (2009)
Fatigue tests were performed on ferritic bainitic steel notched specimens (Kt = 2.5) under load controlled constant amplitude loading. These tests show that under constant amplitude tension compression loading, periodical ... -
Article dans une revue avec comité de lectureSAINTIER, Nicolas;
PALIN-LUC, Thierry; EL DSOKI, Chalid; BIDOUARD, Hadrien; KAUFMANN, Heinz; DUMAS, C.; VÖLLMECKE, F.J.; SONSINO, Cetin Morris (Wiley-VCH Verlag, 2011)
Load controlled fatigue tests were performed up to 107 cycles on flat notched specimens (Kt =2.5) under constant amplitude and variable amplitude loadings with and without periodical overloads. Two materials are studied: ... -
Article dans une revue avec comité de lectureMESSAGER, Alexandre; JUNET, Arnaud; PALIN-LUC, Thierry; BUFFIÉRE, Jean Yves; SAINTIER, Nicolas; RANC, Nicolas; EL MAY, Mohamed; GAILLARD, Yves; KING, Andrew; BONNIN, Anne; NADOT, Yves (Wiley-Blackwell, 2020)This work presents a new ultrasonic fatigue testing device for studying the initiation and propagation mechanisms of internal microstructurally short fatigue cracks using in situ synchrotron tomography. Its principle is ...
-
Article dans une revue avec comité de lectureEL MAY, Mohamed; SAINTIER, Nicolas; PALIN-LUC, Thierry; DEVOS, Olivier; BRUCELLE, Olivier (Elsevier, 2018)This paper presents an analytical model for assessing the corrosion fatigue crack initiation life on a martensitic stainless steel X12CrNiMoV12-3 in high cycle fatigue regime (between 105 and 107 cycles). Based on in-situ ...
-
Effect of Corrosion on the High Cycle Fatigue Strength of Martensitic Stainless Steel X12CrNiMoV12-3 Article dans une revue avec comité de lectureEL MAY, Mohamed; PALIN-LUC, Thierry; SAINTIER, Nicolas; DEVOS, Olivier (Elsevier, 2012)This paper addresses the effects of corrosion on the high cycle fatigue (HCF) strength of a high mechanical strength martensitic stainless steel (X12CrNiMoV12-3) that is used in aeronautic applications. HCF tests (between ...