Quasi-automated reconstruction of the femur from bi-planar X-rays
Article dans une revue avec comité de lecture
Date
2020Journal
Computer Methods in Biomechanics and Biomedical Engineering: Imaging & VisualizationAbstract
3D reconstruction from low-dose Bi-Planar X-Rays (BPXR) is a rising practice in clinical routine. However, this process is time consuming and highly depends on the user. This study aims to partially automate the process for the femur, thus decreasing reconstruction time and increasing robustness. As a training set, 50 femurs are segmented from CT scans together with 120 BPXR reconstructions. From this dataset, an initial solution for the bony contours is defined through Gaussian Process Regression (GPR), using eight digitized landmarks. This initial solution is projected on both x-rays and automatically adjusted using an adapted Minimal Path Algorithm (MPA). To evaluate this method, CT-scans were acquired from 20 cadaveric femurs. For each sample, the CTbased reconstruction is compared to the one automatically generated from the digitally reconstructed radiographs. Euclidean distances between femur reconstructions and the segmented CT data are on average 1.0 mm with a Root Mean Square Error (RMSE) of 0.8 mm. Femoral torsion errors are assessed: the bias is lower than 0.1° with a 95% confidence interval of 4.8°. The proposed method substantially improves 3D reconstructions from BPXR, as it enables a fast and reliable reconstruction, without the need for manual adjustments, which is essential in clinical routine.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureGIRINON, François; BAYOUD, Wael; LAHKAR, Bhrigu; BONNET-LEBRUN, Aurore; LAZENNEC, Jean-Yves; SKALLI, Wafa; ROUCH, Philippe; GAJNY, Laurent (Elsevier BV, 2022-03)Three-dimensional bone reconstructions from medical imaging are essential for biomechanical modelling and are growing tools in clinics. Several methods of lower limbs reconstruction from biplanar radiographs have ...
-
Article dans une revue avec comité de lectureQuantitative measurements of spine shape parameters on planar X-ray images is critical for clinical applications but remains tedious and with no fully-automated solution demonstrated on the whole spine. This study aims to ...
-
Communication avec acte3D reconstruction of the spine using biplanar X-rays remains approximate and requires human-machine interactions to adjust the position of important features such as vertebral corners and endplates. The purpose of this ...
-
Article dans une revue avec comité de lectureEBRAHIMI, Shahin; SKALLI, Wafa; ANGELINI, Elsa D.; GAJNY, Laurent; VERGARI, Claudio (Springer Verlag, 2018)Purpose: To design a quasi-automated three-dimensional reconstruction method of the spine from biplanar X-rays as the daily used method in clinical routine is based on manual adjustments of a trained operator and the ...
-
Vertebral rotation estimation from frontal X-rays using a quasi-automated pedicle detection method Article dans une revue avec comité de lectureEBRAHIMI, Shahin; SKALLI, Wafa; ANGELINI, Elsa D.; GAJNY, Laurent; VERGARI, Claudio (Springer Verlag, 2019)Purpose Measurement of vertebral axial rotation (VAR) is relevant for the assessment of scoliosis. Stokes method allows estimating VAR in frontal X-rays from the relative position of the pedicles and the vertebral body. ...