Scientific ReportsAbstract
AbstractThis work reports a multispectral tomography technique in transmission mode (called 3DITI for 3D Infrared Thermospectroscopic Imaging) based on a middle wavelength infrared (MWIR) focal plane array. This technique relies on an MWIR camera (1.5 to 5.5 μm) used in combination with a multispectral IR monochromator (400 nm to 20 μm), and a sample mounted on a rotary stage for the measurement of its transmittance at several angular positions. Based on the projections expressed in terms of a sinogram, spatial three-dimensional (3D) cubes (proper emission and absorptivity) are reconstructed using a back-projection method based on inverse Radon transform. As a validation case, IR absorptivity tomography of a reflective metallic screw is performed within a very short time, i.e., shorter than 1 min, to monitor 72 angular positions of the sample. Then, the absorptivity and proper emission tomographies of a butane-propane-air burner flame and microfluidic perfluoroalkoxy (PFA) tubing filled with water and ethanol are obtained. These unique data evidence that 3D thermo-chemical information in complex semi-transparent media can be obtained using the proposed 3DITI method. Moreover, this measurement technique presents new problems in the acquisition, storage and processing of big data. In fact, the quantity of reconstructed data can reach several TB (a tomographic sample cube of 1.5 × 1.5 × 3 cm3 is composed of more than 1 million pixels per wavelength).
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Communication avec acteBATSALE, Jean-Christophe; ABISSET-CHAVANNE, Emmanuelle; ACHCHAQ, Fouzia; AOUALI, Abderezak; CHEVALIER, Stéphane; GROZ, Marie-Marthe; MAIRE, Jeremie; SOMMIER, Alain (SPIE, 2023-06-12)The study of the response of a temperature field (recorded from IR cameras) to a laser spot heating is increasingly used for NDE (Non Destructive Evaluation) applications. The most classical type of application is to use ...
-
Article dans une revue avec comité de lectureGROZ, Marie-Marthe; BENSALEM, Mohamed; SOMMIER, Alain; ABISSET-CHAVANNE, Emmanuelle; CHEVALIER, Stéphane; CHULKOW, Arsenii; BATTAGLIA, Jean-Luc; BATSALE, Jean-Christophe; PRADERE, Christophe (MDPI AG, 2020)In this paper, the problem of the quantitative characterization of thermal resistance fields in a multilayer sample is addressed by using the classical front face flash method as the thermal excitation and infrared ...
-
Article dans une revue avec comité de lectureBATTAGLIA, Jean-Luc; RUFFIO, Emmanuel; KUSIAK, Andrzej; PRADERE, Christophe; ABISSET CHAVANNE, Emmanuelle; CHEVALIER, Stéphane; SOMMIER, Alain; BATSALE, Jean-Christophe (Elsevier BV, 2020)The front face photothermal radiometry technique has been improved in order to estimate the thermal conductivity of thin films with better accuracy compared to existing techniques. The experimental pro- cedure is based on ...
-
Article dans une revue avec comité de lectureAOUALI, Abderezak; CHEVALIER, Stéphane; SOMMIER, Alain; AYADI, M.; BATSALE, Jean-Christophe; BALAGEAS, Daniel; PRADERE, Christophe (The Optical Society of America, 2021)Knowledge of the spatial and temporal distribution of heat flux is of great interest for the quantification of heat sources. In this work, we describe the development of a new ultra-broadband contactless imaging power meter ...
-
Article dans une revue avec comité de lectureAOUALI, Abderezak; LAFARGUE-TALLET, Thomas; CHEVALIER, Stéphane; SOMMIER, Alain; PEIFFER, Raymond; TAILLANDIER, Maximilian; BATSALE, Jean-Christophe; PRADERE, Christophe (Informa UK Limited, 2023-07-06)The knowledge of the amplitude and the spatial distribution of an excitation flux is of great interest for the quantification of heat sources. In this work, the development of a non-contact imaging powermeter based on the ...