Development of a Wearable Framework for the Assessment of a Mechanical-Based Indicator of Falling Risk in the Field
Article dans une revue avec comité de lecture
Date
2023Journal
Innovation and Research in BioMedical engineeringRésumé
Objectives: The characterization of the instability of gait is a current challenge of biomechanics. Indeed, risks of falling naturally result from the difficulty to control perturbations of the locomotion pattern. Hence, the assessment of a synthetic parameter able to quantify the instability in real time will be useful for the prevention of falls occurring in this context. Thus, the objective of the present study, in two steps, was to propose and evaluate a relevant parameter to quantifythe risk of fallings.
Material and Methods: Experimental analysis of the gait of 11 able-bodied subjectsfrom a motion capture system in laboratory condition was performed. The distance of the Body Center of Mass (BCOM) to the Minimal Moment Axis (MMA) was computed as a proxy of whole-body angular momentum variations. In a second step, we quantified the kinematics during gait with wearable Inertial Measurement Units (IMU) fixed on two individuals (one able bodied person and one person with transfemoral amputation). We compared the IMU-based BCOM kinematics with a motion capture reference system to verify the accuracy of our measures in the field.
Results: Normative thresholds of the distance of the Body Center of Mass (BCOM) to the Minimal Moment Axis (MMA) during able-bodied level walking were assessed. The average error between the BCoM displacement computed from the IMU and from the reference vicon data of 4 mm, 3 mm and 53 mm on the mediolateral, anteroposterior and vertical axes respectively.
Conclusion: All these results make it possible to consider the determination of the risks of falls in the field at mid-term. the research on an optimal configuration that maintain the performance while simplifying the device will be essential to make it acceptable by the individuals.
Fichier(s) constituant cette publication
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Article dans une revue avec comité de lectureWhile multiple criteria to quantify gait instability exist, some limitations hinder their computation during realistic walking conditions. A descriptor, computed as the distance between the center of mass of the body and ...
-
Article dans une revue avec comité de lecture
FOUGERON, Nolwenn;
BONNET, Xavier;
PANHELLEUX, Brieuc; ROSE, Jean-Loïc;
ROHAN, Pierre-Yves; PILLET, Hélène;
PILLET, Helene (Ovid Technologies (Wolters Kluwer Health), 2024-04)
Background: Transmission of loads between the prosthetic socket and the residual limb is critical for the comfort and walking ability of people with transfemoral amputation. This transmission is mainly determined ... -
Article dans une revue avec comité de lectureLOIRET, Isabelle; VILLA, Coralie; DAURIAC, Boris; BONNET, Xavier; MARTINET, Noël; PAYSANT, Jean;
PILLET, Helene (SAGE Publications, 2019)
Background: Amputee gait is known to be asymmetrical, especially during loading of the lower limb. Monitoring asymmetry could be useful in quantifying patient performance during rehabilitation. Wearable insoles can provide ... -
Article dans une revue avec comité de lectureFOUGERON, Nolwenn;
ROHAN, Pierre-Yves; ROSE, Jean-Loïc; BONNET, Xavier;
PILLET, Helene (Elsevier BV, 2022-07)
The role of the above-knee socket is to ensure the load transfer via the coupling of residual limb-prosthesis with minimal discomfort and without damaging the soft tissues. Modelling is a potential tool to predict socket ... -
Article dans une revue avec comité de lectureSIMONETTI, Emeline; VILLA, Coralie; BASCOU, Joseph; VANNOZZI, Giuseppe; BERGAMINI, Elena;
PILLET, Helene (Springer Science and Business Media LLC, 2019)
In recent years, inertial measurement units (IMUs) have been proposed as an alternative to force platforms and pressure sensors for gait events (i.e., initial and final contacts) detection. While multiple algorithms have ...