Enhanced Torque Control of a PMSM Supplied by a Four-Leg Voltage Source Inverter Using the Third Harmonic
Communication avec acte
Abstract
This paper investigates an electrical drive composed of a four-leg voltage source inverter and a three-phase starconnected surface permanent magnet synchronous machine with concentrated windings. The inverter fourth leg is clamped to the neutral point of the machine. We find the current references leading to smooth torque and maximal torque per ampere operation in the presence of a third harmonic electromotive force component. We further analyze the advantages of the proposed topology in terms of torque increase and dc-link voltage requirements.
Files in this item
- Name:
- L2EP_ICEM_2008_SEMAIL.pdf
- Size:
- 546.0Kb
- Format:
- Description:
- article congres ICEM
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; MOLLET, Yves; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (Institution of Engineering and Technology, 2014)This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the ...
-
Communication avec acteMEINGUET, Fabien; GYSELINCK, Johan; SEMAIL, Eric (IEEE - Institute of Electrical and Electronics Engineers, 2010)This paper deals with an on-line fault detection method for multi-phase PMSM drives. The method is based on the detection of the stator current positive- and negative sequence fundamental components expressed in the ...
-
Communication avec acteMEINGUET, Fabien; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2011)This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit ...
-
Communication avec acteTRABELSI, Mohamed; SEMAIL, Eric; MEINGUET, Fabien; NGUYEN, Ngac Ky (IEEE - Power and Energy Society, 2016)This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For such applications, the fault ...
-
Communication avec acteDOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; SEMAIL, Eric; NGUYEN, Ngac Ky (SGE 2016, 2016)Dans le cadre d’une commande en mode dégradé d’un entrainement comprenant deux machines polyphasées connectées en série et pilotées de façon indépendante, l’article s’intéresse à analyser la performance de l’entrainement ...