Enhanced Torque Control of a PMSM Supplied by a Four-Leg Voltage Source Inverter Using the Third Harmonic

Communication avec acte
Auteur
MEINGUET, Fabien
GYSELINCK, Johan
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]

URI
http://hdl.handle.net/10985/9259
DOI
10.1109/ICELMACH.2008.4799868
Date
2008

Résumé

This paper investigates an electrical drive composed of a four-leg voltage source inverter and a three-phase starconnected surface permanent magnet synchronous machine with concentrated windings. The inverter fourth leg is clamped to the neutral point of the machine. We find the current references leading to smooth torque and maximal torque per ampere operation in the presence of a third harmonic electromotive force component. We further analyze the advantages of the proposed topology in terms of torque increase and dc-link voltage requirements.

Fichier(s) constituant cette publication

Nom:
L2EP_ICEM_2008_SEMAIL.pdf
Taille:
546.0Ko
Format:
PDF
Description:
article congres ICEM
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • A change-detection algorithm for short-circuit fault detection in closed-loop AC drives 
    Article dans une revue avec comité de lecture
    MEINGUET, Fabien; MOLLET, Yves; GYSELINCK, Johan; ccSEMAIL, Eric; ccKESTELYN, Xavier (Institution of Engineering and Technology, 2014)
    This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the ...
  • An On-line Method for Stator Fault Detection in Multi-phase PMSM Drives 
    Communication avec acte
    MEINGUET, Fabien; GYSELINCK, Johan; ccSEMAIL, Eric (IEEE - Institute of Electrical and Electronics Engineers, 2010)
    This paper deals with an on-line fault detection method for multi-phase PMSM drives. The method is based on the detection of the stator current positive- and negative sequence fundamental components expressed in the ...
  • Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives 
    Communication avec acte
    MEINGUET, Fabien; GYSELINCK, Johan; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2011)
    This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit ...
  • Procédé de commande d'un moteur électrique à 3 phases alimentée indépendamment 
    Brevet
    BRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; ccSEMAIL, Eric; ccKESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)
    Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...
  • Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Short-Circuit Inverter Fault 
    Article dans une revue avec comité de lecture
    MEINGUET, Fabien; ccSEMAIL, Eric; ccKESTELYN, Xavier; ccNGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)
    Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts

Lettre Diffuser la Science

Dernière lettreVoir plus

Statistiques de consultation

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales