A change-detection algorithm for short-circuit fault detection in closed-loop AC drives

Article dans une revue avec comité de lecture
Author
MEINGUET, Fabien
MOLLET, Yves
GYSELINCK, Johan
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
ccKESTELYN, Xavier

URI
http://hdl.handle.net/10985/7340
DOI
10.1049/iet-epa.2012.0316
Date
2014
Journal
IET Electric Power Applications

Abstract

This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the voltage. Therefore, an appropriate diagnostic index is proposed, which is derived from the positive- and negative-sequences of the voltage references. These sequences are obtained in the time domain via adaptive filters, which require only a few calculations. To increase the sensitivity to the fault, the algorithm is only applied to a part of the voltage references, i.e. the output of the proportional-integral controllers. Further, the cumulative-sum algorithm is introduced to cope with changes of small magnitudes. This algorithm allows a change of a fault index to be detected and can be used as a decision system. The resulting fault detection scheme is computationally cheap and can be embedded in the control unit. Simulations and experimental results validate the proposed method in steady state and the performances under non-stationary operating conditions are also investigated.

Files in this item

Name:
L2EP_IET Power Applications_20 ...
Size:
1.140Mb
Format:
PDF
View/Open

Collections

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Related items

Showing items related by title, author, creator and subject.

  • Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives 
    Communication avec acte
    MEINGUET, Fabien; GYSELINCK, Johan; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2011)
    This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit ...
  • Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives 
    Communication avec acte
    MEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li; ccSEMAIL, Eric; ccKESTELYN, Xavier; NGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)
    A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ...
  • Computation of Optimal Current References for Flux-weakening of Multi-Phase Synchronous Machines 
    Communication avec acte
    LU, Li; ASLAN, Bassel; KOBYLANSKI, Luc; SANDULESCU, Paul; MEINGUET, Fabien; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2012)
    Multi-phase synchronous machines are more and more used in specific applications where high power density, low bus voltage, wide speed range and fault-tolerant capabilities are required. Due to the high number of degrees ...
  • Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Short-Circuit Inverter Fault 
    Article dans une revue avec comité de lecture
    MEINGUET, Fabien; ccSEMAIL, Eric; ccKESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)
    Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
  • Procédé de commande d'un moteur électrique à 3 phases alimentée indépendamment 
    Brevet
    BRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; ccSEMAIL, Eric; ccKESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)
    Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...

Browse

All SAMCommunities & CollectionsAuthorsIssue DateCenter / InstitutionThis CollectionAuthorsIssue DateCenter / Institution

Newsletter

Latest newsletterPrevious newsletters

Statistics

Most Popular ItemsStatistics by CountryMost Popular Authors

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales