Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives

Communication avec acte
Auteur
MEINGUET, Fabien
GYSELINCK, Johan
ccSEMAIL, Eric
13338 Laboratoire d’Électrotechnique et d’Électronique de Puissance - ULR 2697 [L2EP]
ccKESTELYN, Xavier

URI
http://hdl.handle.net/10985/6822
DOI
10.1109/ISIE.2011.5984483
Date
2011

Résumé

This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit and current sensor outage. The method is based on the monitoring of the abc currents with phase-locked loops and the ‘CUSUM’ algorithm for the decision system. The impact of the considered faults is examined: first, in case there is no modification of the control and then in case a control reconfiguration is performed taking into account the fault diagnosis. Closed-loop operation is performed before, during and after the fault. Experimental results show that the latter case allows maintaining the drive in safe operation.

Fichier(s) constituant cette publication

Nom:
ISIE_full_paper_Meinguet_v4.pdf
Taille:
564.0Ko
Format:
PDF
Description:
document article principal
Voir/Ouvrir

Cette publication figure dans le(s) laboratoire(s) suivant(s)

  • Laboratoire d'Electrotechnique et d'Electronique de Puissance (L2EP) de Lille

Documents liés

Visualiser des documents liés par titre, auteur, créateur et sujet.

  • A change-detection algorithm for short-circuit fault detection in closed-loop AC drives 
    Article dans une revue avec comité de lecture
    MEINGUET, Fabien; MOLLET, Yves; GYSELINCK, Johan; ccSEMAIL, Eric; ccKESTELYN, Xavier (Institution of Engineering and Technology, 2014)
    This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the ...
  • Signal-based Technique for Fault Detection and Isolation of Inverter Faults in Multi-phase Drives 
    Communication avec acte
    MEINGUET, Fabien; SANDULESCU, Paul; ASLAN, Bassel; LU, Li; ccSEMAIL, Eric; ccKESTELYN, Xavier; NGUYEN, Ngac Ky (IEEE - Institute of Electrical and Electronics Engineers, 2012)
    A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An analysis of simulations in faulty conditions leads to the derivation of suitable fault indices. These are based ...
  • Computation of Optimal Current References for Flux-weakening of Multi-Phase Synchronous Machines 
    Communication avec acte
    LU, Li; ASLAN, Bassel; KOBYLANSKI, Luc; SANDULESCU, Paul; MEINGUET, Fabien; ccSEMAIL, Eric; ccKESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2012)
    Multi-phase synchronous machines are more and more used in specific applications where high power density, low bus voltage, wide speed range and fault-tolerant capabilities are required. Due to the high number of degrees ...
  • Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive with Short-Circuit Inverter Fault 
    Article dans une revue avec comité de lecture
    MEINGUET, Fabien; ccSEMAIL, Eric; ccKESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)
    Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
  • Procédé de commande d'un moteur électrique à 3 phases alimentée indépendamment 
    Brevet
    BRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; ccSEMAIL, Eric; ccKESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)
    Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...

Parcourir

Tout SAMLaboratoiresAuteursDates de publicationCampus/InstitutsCe LaboratoireAuteursDates de publicationCampus/Instituts

Lettre Diffuser la Science

Dernière lettreVoir plus

Statistiques de consultation

Publications les plus consultéesStatistiques par paysAuteurs les plus consultés

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales

ÉCOLE NATIONALE SUPERIEURE D'ARTS ET METIERS

  • Contact
  • Mentions légales