Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives
Communication avec acte
Abstract
This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit and current sensor outage. The method is based on the monitoring of the abc currents with phase-locked loops and the ‘CUSUM’ algorithm for the decision system. The impact of the considered faults is examined: first, in case there is no modification of the control and then in case a control reconfiguration is performed taking into account the fault diagnosis. Closed-loop operation is performed before, during and after the fault. Experimental results show that the latter case allows maintaining the drive in safe operation.
Files in this item
- Name:
- ISIE_full_paper_Meinguet_v4.pdf
- Size:
- 564.0Kb
- Format:
- Description:
- document article principal
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; MOLLET, Yves; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (Institution of Engineering and Technology, 2014)This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the ...
-
Flux-weakening operation of open-end winding drive integrating a cost effective high-power charger Article dans une revue avec comité de lectureIn this paper, a three-phase drive with a six-leg Voltage Source Inverter (VSI) and an open-end winding Interior Permanent Magnet Synchronous Machine (IPMSM) designed for the traction of an electric vehicle is studied in ...
-
Article dans une revue avec comité de lectureSANDULESCU, Paul; MEINGUET, Fabien; BRUYERE, Antoine; SEMAIL, Eric; KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2014)This paper presents and compares control strategies for three-phase open-end winding drives operating in the flux-weakening region. A six-leg inverter with a single dc-link is associated with the machine in order to use a ...
-
Communication avec acteMulti-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SANDULESCU, Paul; SEMAIL, Eric; KESTELYN, Xavier (Institute of Electrical and Electronics Engineers, 2013)A general method for fault detection and isolation is proposed and applied to inverter faults in drives of electric vehicles. This method is based on a change-detection algorithm, which allows multiple fault indices to be ...