Fault Detection, Isolation and Control Reconfiguration of Three-Phase PMSM Drives
Communication avec acte
Abstract
This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit and current sensor outage. The method is based on the monitoring of the abc currents with phase-locked loops and the ‘CUSUM’ algorithm for the decision system. The impact of the considered faults is examined: first, in case there is no modification of the control and then in case a control reconfiguration is performed taking into account the fault diagnosis. Closed-loop operation is performed before, during and after the fault. Experimental results show that the latter case allows maintaining the drive in safe operation.
Files in this item
- Name:
- ISIE_full_paper_Meinguet_v4.pdf
- Size:
- 564.0Kb
- Format:
- Description:
- document article principal
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; MOLLET, Yves; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (Institution of Engineering and Technology, 2014)This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
-
BrevetBRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; SEMAIL, Eric; KESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...
-
Flux-weakening operation of open-end winding drive integrating a cost effective high-power charger Article dans une revue avec comité de lectureIn this paper, a three-phase drive with a six-leg Voltage Source Inverter (VSI) and an open-end winding Interior Permanent Magnet Synchronous Machine (IPMSM) designed for the traction of an electric vehicle is studied in ...
-
Communication avec acteMulti-phase machines are known for their fault-tolerant capability. However, star-connected machines have no fault tolerance to inverter switch short-circuit fault. This paper investigates the fault-tolerant operation of ...