An On-line Method for Stator Fault Detection in Multi-phase PMSM Drives
Communication avec acte
Abstract
This paper deals with an on-line fault detection method for multi-phase PMSM drives. The method is based on the detection of the stator current positive- and negative sequence fundamental components expressed in the stationary αβ reference frame. These components allow calculating a fault index used for the detection of stator faults, such as open-circuit faults. The decision criterion is based on the CUSUM algorithm. A model of a five-phase machine with one single-phase open-circuit is derived and validated with experimental results. Then, it is shown that the proposed method achieves fault detection on a wide speed range and even during speed transient.
Files in this item
- Name:
- VPPC_Full_paper_Meinguet_IEEE_ ...
- Size:
- 1.009Mb
- Format:
- Description:
- document article principal
Related items
Showing items related by title, author, creator and subject.
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; MOLLET, Yves; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (Institution of Engineering and Technology, 2014)This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the ...
-
Communication avec acteMEINGUET, Fabien; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2011)This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit ...
-
Communication avec acteThis paper investigates an electrical drive composed of a four-leg voltage source inverter and a three-phase starconnected surface permanent magnet synchronous machine with concentrated windings. The inverter fourth leg ...
-
Communication avec acteTRABELSI, Mohamed; SEMAIL, Eric; MEINGUET, Fabien; NGUYEN, Ngac Ky (IEEE - Power and Energy Society, 2016)This paper describes analytical and simulation tools to analyze the effects of Open Switch Fault (OSF) and Open Phase Fault (OPF) on five-phase PMSM designed for aerospace applications. For such applications, the fault ...
-
Communication avec acteDOS SANTOS MORAES, Tiago José; MEINGUET, Fabien; GUERIN, Mael; SEMAIL, Eric; NGUYEN, Ngac Ky (SGE 2016, 2016)Dans le cadre d’une commande en mode dégradé d’un entrainement comprenant deux machines polyphasées connectées en série et pilotées de façon indépendante, l’article s’intéresse à analyser la performance de l’entrainement ...