An On-line Method for Stator Fault Detection in Multi-phase PMSM Drives
Communication avec acte
Résumé
This paper deals with an on-line fault detection method for multi-phase PMSM drives. The method is based on the detection of the stator current positive- and negative sequence fundamental components expressed in the stationary αβ reference frame. These components allow calculating a fault index used for the detection of stator faults, such as open-circuit faults. The decision criterion is based on the CUSUM algorithm. A model of a five-phase machine with one single-phase open-circuit is derived and validated with experimental results. Then, it is shown that the proposed method achieves fault detection on a wide speed range and even during speed transient.
Fichier(s) constituant cette publication
- Nom:
- VPPC_Full_paper_Meinguet_IEEE_ ...
- Taille:
- 1.009Mo
- Format:
- Description:
- document article principal
Cette publication figure dans le(s) laboratoire(s) suivant(s)
Documents liés
Visualiser des documents liés par titre, auteur, créateur et sujet.
-
Communication avec acteThis paper investigates an electrical drive composed of a four-leg voltage source inverter and a three-phase starconnected surface permanent magnet synchronous machine with concentrated windings. The inverter fourth leg ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; MOLLET, Yves; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (Institution of Engineering and Technology, 2014)This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the ...
-
Communication avec acteMEINGUET, Fabien; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2011)This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit ...
-
Communication avec acteLU, Li; ASLAN, Bassel; KOBYLANSKI, Luc; SANDULESCU, Paul; MEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2012)Multi-phase synchronous machines are more and more used in specific applications where high power density, low bus voltage, wide speed range and fault-tolerant capabilities are required. Due to the high number of degrees ...
-
Article dans une revue avec comité de lectureJOSE DOS SANTOS MORAES, Tiago; TRABELSI, Mohamed; NGUYEN, Ngac Ky; SEMAIL, Eric; MEINGUET, Fabien (Institution of Engineering and Technology, 2020)This paper investigates a real-time fault diagnostic of a transportation system which needs two drives with fault-tolerance capabilities. Because of constraints on the mass of the system and on the cost of the Voltage ...