A change-detection algorithm for short-circuit fault detection in closed-loop AC drives
Article dans une revue avec comité de lecture
Date
2014Journal
IET Electric Power ApplicationsAbstract
This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the voltage. Therefore, an appropriate diagnostic index is proposed, which is derived from the positive- and negative-sequences of the voltage references. These sequences are obtained in the time domain via adaptive filters, which require only a few calculations. To increase the sensitivity to the fault, the algorithm is only applied to a part of the voltage references, i.e. the output of the proportional-integral controllers. Further, the cumulative-sum algorithm is introduced to cope with changes of small magnitudes. This algorithm allows a change of a fault index to be detected and can be used as a decision system. The resulting fault detection scheme is computationally cheap and can be embedded in the control unit. Simulations and experimental results validate the proposed method in steady state and the performances under non-stationary operating conditions are also investigated.
Files in this item
Related items
Showing items related by title, author, creator and subject.
-
Communication avec acteMEINGUET, Fabien; GYSELINCK, Johan; SEMAIL, Eric; KESTELYN, Xavier (IEEE - Institute of Electrical and Electronics Engineers, 2011)This paper deals with on-line software fault detection and isolation method for a drive composed of a fourleg inverter and a three-phase permanent magnet synchronous machine. The considered faults are single-phase open-circuit ...
-
Communication avec acteMEINGUET, Fabien; GYSELINCK, Johan; SEMAIL, Eric (IEEE - Institute of Electrical and Electronics Engineers, 2010)This paper deals with an on-line fault detection method for multi-phase PMSM drives. The method is based on the detection of the stator current positive- and negative sequence fundamental components expressed in the ...
-
Communication avec acteThis paper investigates an electrical drive composed of a four-leg voltage source inverter and a three-phase starconnected surface permanent magnet synchronous machine with concentrated windings. The inverter fourth leg ...
-
Article dans une revue avec comité de lectureMEINGUET, Fabien; SEMAIL, Eric; KESTELYN, Xavier; NGUYEN, Ngac Ky (Institute of Electrical and Electronics Engineers, 2016)Multi-phase machines are well-known for their fault tolerant capability. Star-connected multiphase machines have fault tolerance in open-circuit. For inverter switch short-circuit fault, it is possible to keep a smooth ...
-
BrevetBRUYERE, Antoine; MEINGUET, Fabien; SANDULESCU, Paul; SEMAIL, Eric; KESTELYN, Xavier (VALEO SYSTEMES DE CONTROLE MOTEUR, 2013)Le système d’entraînement rotatif comporte : - une source de tension continue (102) ; - un moteur électrique (104) présentant un axe de rotation (A), et comportant des phases indépendantes (a, b, c) présentant des directions ...